clinical comparison trials diaton tonometer

Content: “Collection of Articles and Clinical Studies on Diaton Scleral Transpalpebral Tonometer:

Download PDF Collection of Articles and Clinical Studies 2019 – Diaton Tonometer

General Information 3
Comparison of Intraocular Pressure before and after Laser In
Situ Keratomileusis Refractive Surgery Measured with Perkins
Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry
(Isabel Cacho, Juan Sanchez-Naves, Laura Batres,
Jesús Pintor, and Gonzalo Carracedo)
5
Change in Intraocular Pressure During Point-of-Care Ultrasound
(Cameron Berg, MD; Stephanie J. Doniger, MD; Brita Zaia, MD;
Sarah R. Williams)
14
Tonometer through the eyelid diaton: accuracy and quick IOP reading
(Juan Conzalo Carracedo Rodriguez, MSc, PhD)
16
Agreement among Transpalpebral, Transcleral and Tactile
Intraocular Pressure Measurements in Eyes with Type 1 Boston
Keratoprosthesis
(Jessica L. Liu, Thasarat S. Vajaranant, Maria S. Cortina, Jacob T.
Wilensky)
20
Comparative agreement among three methods of tonometry:
Goldmann applanation, diaton traspalpebral and dynamic contour
(Luis A. Zarate, Magdalena Garcia-Huerta, Rafael Castañe da
Diez, Mauricio Turati, Felix Gi Carrasco, Jesus Jimenez-Roman,
Jose A. Paczka)
22
Comparison of IOP measurements between Goldmann
Applanation Tonometry and Ballistic Principle Diaton Tonometry
in several groups of patients
(N. Michailidou, A. Polychronakos)
23
Comparison of Accuracy of Diaton Transpalpebral
Tonometer Versus Goldmann Applanation Tonometer,
Dynamic Contour Tonometer and Ocular
Response Analyzer
(Henry D. Perry, M.D.; S.E. Avetisov, M.D.; V.P. Erichev, M.D.;
А.А. Antonov, M.D.; А.R. Illarionova, M.D.)
26
Accuracy of Transpalpebral Tonometer Compared
to Goldmann Applanation Tonometer in Normal
and Glaucomatous Eyes
(M.A. Latina, T.A. Shazly , R. Iospa, E.W. Chynn)
29
Handheld tonometer offers simple, reliable way to measure IOP
Pen-like tonometer designed to be patient-friendly
(Jennifer A. Webb)
32
Eye pressure measurement for glaucoma detection and
treatment
(Seppo similä LKT company, the head of research, Pedihealth Oy
Company, Oulu, Finland)
34
Transpalpebral diaton tonometer: what’s ahead?
Decking the halls with new products
(Maxine Lipner, EyeWorld Senior Contributing Editor)
41
Transpalpebral tonometer application during
intraocular pressure evaluation in the patients
with refraction anomaly before and after
keratophotorefractive surgery
(Prof. A.P. Nesterov, M.D.; T.B. Dzhafarli, M.D.; A.R. Illarionova, M.D.)
42
Comparison of the Diaton Transpalpebral Tonometer Versus
Goldmann Applanation
(R.S. Davidson, N. Faberowski, R.J. Noecker, M.Y. Kahook)
46
Comparison of the Diaton Transpalpebral Tonometer Versus
Tono-Pen Applanation
(Theodore H. Curtis, M.D.; Douglas L. Mackenzie, M.D.;
Robert J. Noecker, M.D.; and Malik Y. Kahook, M.D.)
48
Clinical comparison of the Diaton and the Non-contact Tonometers
with the Goldmann applanation tonometer in glaucoma patients
(A.P. Nesterov, A.R. Illarionova, B.V.Obruch)
51
Clinical use of transpalpebral scleral diaton tonometer in pediatrics
(Professor E.I. Sidorenko, E.Y. Markova)
53